Most laid scrim data sheets look disarmingly simple: a few item codes, a mesh size column, a weight column, maybe a roll width. Four columns, thirty seconds, done — you order the cheapest line that fits your grammage budget and move on.
That reading costs people money. The same “5×5 mm” grid can weigh anywhere from 3 to 70 g/m² depending on yarn and construction. Two web pages can quote slightly different weights for the same item code. And the fields that decide whether your line runs cleanly — tensile, elongation, binder tolerance — are usually not on the public sheet at all. This article walks through a spec sheet the way our own quoting team reads one, using real numbers from published GADTEX (RUIFIBER GROUP) data sheets.
Every line on a scrim data sheet is a compressed sentence. Taking the naming our own pages use (manufacturer’s convention), a typical code breaks down like this:
| Segment | Example | What it tells you |
|---|---|---|
| Prefix | CF / CP / CM / CFT / PE | Yarn family: CF = fiberglass, CP = polyester, CM = fiberglass mesh construction, CFT = fiberglass triaxial, PE = polyester net |
| Pitch numbers | 5*5 / 12.5*30*30 / 12.5*12.5*12.5 | Mesh opening in mm; two numbers = biaxial, three = triaxial |
| Suffix | PH | Binder system code (PVOH in this convention); other pages list PVC, Acrylic, or “customized” |
| Weight column | 6.2–6.6 g/m² | Areal weight, usually a range, not a single number |
So CFT12.5*12.5*12.5PH reads as: fiberglass triaxial scrim, 12.5 mm openings in three directions, PVOH-bonded. Once you can parse the code, you can sanity-check almost any quote before you open the spreadsheet — for example, a “triaxial” quote with only two pitch numbers is a red flag, something our triaxial construction article explains in depth: triaxial vs biaxial construction.
GSM (grams per square meter) is the number everyone compares and the one most often misread. It is a real, measurable property — but it is an output of three other choices (yarn tex, yarn count per direction, single or double yarn), not an independent setting.
| Item | Mesh | Weight (g/m²) | Why the spread |
|---|---|---|---|
| CP5*5PH | 5×5 mm | 3–5 | Fine single yarn |
| CP2.5*5PH | 2.5×5 mm | 5.5–6 | Denser pitch |
| CP4*4PH | 4×4 mm | 65–70 | Double/heavier yarn at similar pitch |
Same family, similar millimeter openings — a more-than-tenfold weight difference. The lesson: mesh pitch does not predict GSM, and GSM does not tell you the pitch. A 20 g/m² scrim could be a dense fine-yarn grid or a sparse heavy-yarn one, and those two behave very differently in impregnation and tear arrest. Always read the two columns together.

Pitch (the mm spacing between yarns) controls two things that pull in opposite directions:
Our published pitch range runs from 0.8 to 3 yarns per cm — openings from about 2.5 mm up to 30 mm and beyond. For foil and film lines, open area usually wins; for nonwoven and tissue reinforcement, crossing density usually wins. Where your product sits between those poles is the single most useful question to answer before quoting a pitch. For composites specifically, the same logic extends into scrim-and-nonwoven combinations: see our composite reinforcement page.

Here is the honest part: published laid scrim sheets, including ours, typically list item number, mesh size, and weight — and stop. The fields that decide line performance are usually only in a full technical data sheet or a sample trial. Before you commit an order, ask:
| Missing field | Why it matters | What to request |
|---|---|---|
| Tensile strength (MD/CD, N/50mm or kN/m) | The actual reinforcement value you are buying | Measured values per direction, not “high tensile” adjectives — note our public pages list tensile as a characteristic word, not a number |
| Elongation at break | Predicts dimensional behavior in calendering and lamination | Low-elongation values per direction |
| Binder type and temperature window | PVOH behaves differently from PVC or acrylic in wet-out and burn-off | Binder code plus processing limits |
| Width and roll-length tolerances | Affects slitting plans and splice counts | Stated tolerance, not just nominal 200–2500 mm |
| Pitch tolerance | Hand-built lays can drift; ask how it is controlled | Tolerance statement or inspection method |
A supplier who answers these five questions with numbers is telling you something no data sheet can.
While preparing this article we checked our own published numbers, and they are a useful caution. The fiberglass CF5*5 item is listed at 15.2 g/m² on one product page and “15 g/m²” in a summary table on a news page. For CP4*6PH, our news summary table says 4.1 g/m² while a third-party B2B listing shows a different range. Neither is a typo in the interesting sense: summary tables round, product revisions drift, and marketplace listings can lag.

Is higher GSM always stronger?
Not necessarily. GSM measures mass, and strength comes from yarn type, tex, and orientation. A dense fine-yarn scrim and a sparse heavy-yarn scrim can share a GSM while pulling very differently. Ask for tensile per direction instead of relying on weight.
How do I choose mesh pitch?
Start from your process: fast wet-out and full impregnation push you to larger openings; support for thin substrates pushes you to finer pitch. Our carrier selection guide for membrane lines and the duct-facing specification guide both walk through pitch decisions with real line examples: membrane carrier guide, FSK facing guide.
Why do two suppliers’ data sheets show different numbers for a similar scrim?
Different yarn tex, different measuring standards, or simply different sheet versions. Ask each supplier for a dated technical data sheet and compare item codes field by field — see the version-checking case above.
What does PH in an item code mean?
In our naming convention it marks the PVOH (polyvinyl alcohol) binder family; other binders appear as PVC, Acrylic, or “customized”. Binder choice affects wet-out, adhesion, and burn-off behavior, so it belongs in your RFQ alongside pitch and GSM.
If you would rather not decode a spec sheet alone, send us your laminate stack-up and line parameters — contact GADTEX here and we will return a construction proposal with the fields filled in.